EasyManua.ls Logo

Danfoss PVED-CLS - Page 22

Danfoss PVED-CLS
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 | © Danfoss | August 2018 AQ00000211
ENGINEERING TOMORROW
Entry
Point
Auto-Guidance lockout
Guidance machine status flags to both auto-guidance
controllers
Request reset command status: Reset not required
Steering input position status: Not available
Machine can execute commands: Not available
Machine system lockout: Active
Guidance limit status: Not limited
Other steering
device selected
OFF_ROAD AND
GPS_EN AND
CHANGE_EN AND
STW_OFF AND
AUX_OFF AND
NOT SAFE_STATE
Auto-Guidance Qualification
Auto-Guidance communication state machine
Guidance machine status flags to the selected auto-
guidance controller
Request reset command status: Reset not required
Steering input position status: Incorrect position
Machine can execute commands: System is not ready
Machine system lockout: Inactive
Guidance limit status: not limited
Guidance exit reason: Operator override of function
Guidance machine status flags to the deselected auto-
guidance controller
Request reset command status: Reset not required
Steering input position status: Not available
Machine can execute commands: Not available
Machine system lockout: Active
Guidance limit status: not limited
Guidance exit reason: Alternate guidance system active
NOT (OFF_ROAD AND
GPS_EN) AND
NOT SAFE_STATE
NOT
SAFE
STATE
STW_OFF AND
AUX_OFF AND
OFF_ROAD AND
GPS_EN AND
CHANGE_EN AND
NOT
SAFE_STATE
(STW_ON OR
AUX_ON) AND
OFF_ROAD AND
GPS_EN AND
NOT
SAFE_STATE
(NOT GPS_EN OR
NOT OFF_ROAD OR
NOT CHANGE_EN) AND
NOT SAFE_STATE
Safe State
OFF_ROAD AND
GPS_EN AND
CHANGE_EN AND
(STW_ON OR AUX_ON)
AND NOT SAFE_STATE
SAFE_STATE
SAFE_STATE
SAFE_STATE
Guidance machine status flags to both auto-guidance
controllers
Request reset command status: Reset not required
Steering input position status: Not available
Machine can execute commands: Not available
Machine system lockout: Active
Guidance limit status: non recoverable fault
Guidance exit reason: Error
Entry
Point
Auto-Guidance
timeout
Auto-Guidance
invalid command
Auto-Guidance
Valid Command
From selected auto-guidance
controller:
VALID_COMMAND AND
GPS_EN AND
CHANGE_EN
From selected auto-guidance
controller:
Commands not received in time
From selected auto-guidance
controller:
VALID_COMMAND on time
AND GPS_EN AND
CHANGE_EN
NOT CHANGE_EN
NOT
CHANGE_EN
NOT CHANGE_EN
Device change
not allowed
Device change
not allowed
Guidance machine status flags to the selected auto-
guidance controller
Request reset command status: Reset not required
Steering input position status: Correct position
Machine can execute commands: System is not ready
Machine system lockout: Inactive
Guidance limit status: not limited
Guidance exit reason: Remote command timeout
Guidance machine status flags to the selected auto-
guidance controller
Request reset command status: Reset not required
Steering input position status: Correct position
Machine can execute commands: System is not ready
Machine system lockout: Inactive
Guidance limit status: not limited
Guidance exit reason: Remote command out of range/invalid
From selected auto-
guidance controller:
INVALID_COMMAND on
time AND GPS_EN
From selected auto-
guidance controller:
INVALID_COMMAND
AND
CHANGE_EN
From selected auto-
guidance controller:
Commands not
received in time
AND
CHANGE_EN
Figure 8