94 | © Danfoss | August 2018 AQ00000211
ENGINEERING TOMORROW
Name
Address
Data type
Unit
Description of parameter
User
Range
Danfoss default
value
Safety critical
parameters ‘S’
Min.
Max.
STW soft-stop wheel
angle region start
P3562 U16 IR
Defines the wheel angle region start, from the max possible wheel angle
towards 0, in which the soft stop has to be applied
OEM 0 1000 400
STW soft-stop max flow
@ cylinder end-stop
P3564 U16 IR Oil flow to deliver at the max possible wheel angle OEM 0 1000 0
STW soft-stop wheel
angle region end
P3566 U16 IR
Defines the wheel angle region end, from the max possible wheel angle
towards 0, in which the soft stop region shall end
OEM 0 1000 0
Table 40