Language package 3
English, German, Slovenian, Bulgarian, Serbian, Romanian,
Hungarian, Czech and Russian.
Language package 4
English, German, Spanish, English US, Greek, Brazilian
Portuguese, Turkish and Polish.
To order frequency converters with a different language
package, contact the local sales office.
NOTE
For power sizes over 75 kW, see the VLT
®
AutomationDrive
FC 300 90-1400 kW Design Guide.
Description Pos Possible choices
Product group 1-3 FC 30x
Drive series 4-6 301: FC 301
302: FC 302
Power rating 8-10 0.25-75 kW
Phases 11 Three phases (T)
Mains voltage 11-
12
T 2: 200-240V AC
T 4: 380-480V AC
T 5: 380-500V AC
T 6: 525-600V AC
T 7: 525-690V AC
Enclosure 13-
15
E20: IP20
E55: IP 55/NEMA Type 12
P20: IP20 (with back plate)
P21: IP21/ NEMA Type 1 (with back
plate)
P55: IP55/ NEMA Type 12 (with back
plate)
Z20: IP 20
1)
E66: IP 66
RFI filter 16-
17
H1: RFI filter class A1/B1
H2: RFI filter, class A2
H3: RFI filter class A1/B1
1)
H4: RFI filter, class A1 (690 V, FC 302 B2,
C2)
HX: No filter (600V only)
Brake 18 B: Brake chopper included
X: No brake chopper included
T: Safe Stop No brake
1)
U: Safe stop brake chopper
1)
Display 19 G: Graphical Local Control Panel (LCP)
N: Numerical Local Control Panel (LCP)
X: No Local Control Panel
Coating PCB 20 C: Coated PCB
X. No coated PCB
Description Pos Possible choices
Mains option 21 X: No mains option
1: Mains disconnect
3: Mains disconnect and Fuse
2)
5: Mains disconnect, Fuse and Load
sharing
2, 3)
7: Fuse
2)
8: Mains disconnect and Load sharing
3)
A: Fuse and Load sharing
2, 3)
D: Load sharing
3)
Adaptation 22 X: Standard cable entries
O: European metric thread in cable
entries (A4, A5, B1, B2, C1, C2 only)
S: Imperial cable entries (A5, B1, B2, C1
and C2 only)
Adaptation 23 X: No adaptation
Software
release
24-
27
SXXX: Latest release - standard software
Software
language
28 X: Not used
1): FC 301/frame size A1 only
2) US Market only
3): A and B frames have load-sharing built-in by default
Table 5.3 Ordering Type Code Frame Sizes A, B
and C
Description Pos Possible choices
A options 29-
30
AX: No A option
A0: MCA 101 Profibus DP V1 (standard)
A4: MCA 104 DeviceNet (standard)
A6: MCA 105 CANOpen (standard)
AN: MCA 121 Ethernet IP
AL: MCA 120 ProfiNet
AQ: MCA 122 Modbus TCP
AT: MCA 113 Profibus converter
VLT3000
AU: MCA 114 Profibus Converter
VLT5000
AY: MCA 123 Powerlink
A8: MCA 124 EtherCAT
B options 31-
32
BX: No option
BK: MCB 101 General purpose I/O
option
BR: MCB 102 Encoder option
BU: MCB 103 Resolver option
BP: MCB 105 Relay option
BZ: MCB 108 Safety PLC Interface
B2: MCB 112 PTC Thermistor Card
B4: MCB 114 VLT Sensor Input
B6: MCB 150 Safe Option TTL
B7: MCb 151 Safe Option HTL
How to Order
VLT
®
AutomationDrive FC 300 Design Guide, 0.25-75 kW
88 MG33BE02 - VLT
®
is a registered Danfoss trademark
55
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-21462-Danfoss-131B8966-VLT-Automation-VT-Drive-VFD-FC301-230V-5-HP.aspx

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Related product manuals