Option
Name
Description
[121]
Remote ref active
Output is high when parameter 3-13 Reference Site = [1] Remote or [0] Linked to hand/auto while
the LCP.
[122]
No alarm
Output is high when no alarm is present.
[123]
Start command ac-
tive
Output is high when the start command is high (that is via digital input, bus connection, [Hand
On], or [Auto On]), and a stop has been the last command.
[124]
Running reverse
Output is high when the drive is running counterclockwise (the logical product of the status bits
running AND reverse).
[125]
Drive in hand mode
Output is high when the drive is in hand-on mode (as indicated by the LED light above [Hand
On]).
[126]
Drive in auto mode
Output is high when the drive is in auto-on mode (as indicated by LED light on above [Auto
On]).
[151]
ATEX ETR cur. alarm
Selectable if parameter 1-90 Motor Thermal Protection is set to [20] ATEX ETR or [21] Advanced ETR.
If alarm 164, ATEX ETR cur.lim.alarm is active, the output is 1.
[152]
ATEX ETR freq.
alarm
Selectable if parameter 1-90 Motor Thermal Protection is set to [20] ATEX ETR or [21] Advanced ETR.
If alarm 166, ATEX ETR freq.lim.alarm is active, the output is 1.
[153]
ATEX ETR cur. warn-
ing
Selectable if parameter 1-90 Motor Thermal Protection is set to [20] ATEX ETR or [21] Advanced ETR.
If alarm 163, ATEX ETR cur.lim.warning is active, the output is 1.
[154]
ATEX ETR freq.
warning
Selectable if parameter 1-90 Motor Thermal Protection is set to [20] ATEX ETR or [21] Advanced ETR.
If warning 165, ATEX ETR freq.lim.warning is active, the output is 1.
[173]
10Wh counter pulse
[178]
RS Flipflop 8
See parameter group 13-1* Comparators.
[179]
RS Flipflop 9
See parameter group 13-1* Comparators.
[180]
Clock fault
[181]
Prev. Maintenance
[188]
AHF Capacitor Con-
nect
[189]
External Fan Control
The internal logics for the internal fan control is transferred to this output to make it possible to
control an external fan (relevant for hp duct cooling).
[190]
Safe Function active
[191]
Safe Opt. Reset req.
[192]
RS Flipflop 0
See parameter group 13-1* Comparators.
[193]
RS Flipflop 1
See parameter group 13-1* Comparators.
[194]
RS Flipflop 2
See parameter group 13-1* Comparators.
[195]
RS Flipflop 3
See parameter group 13-1* Comparators.
[196]
RS Flipflop 4
See parameter group 13-1* Comparators.
[197]
RS Flipflop 5
See parameter group 13-1* Comparators.
[198]
RS Flipflop 6
See parameter group 13-1* Comparators.
AU275636650261en-000101 / 130R0334214 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals