Danfoss VLT FC 103 Programming Guide

Danfoss VLT FC 103
203 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #171 background imageLoading...
Page #171 background image
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
1-6* Load Depen. Setting
1-60 Low Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-61 High Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-62 Slip Compensation 0 % All set-ups TRUE 0 Int16
1-63 Slip Compensation Time Constant ExpressionLimit All set-ups TRUE -2 Uint16
1-64 Resonance Dampening 100 % All set-ups TRUE 0 Uint16
1-65
Resonance Dampening Time
Constant 5 ms All set-ups TRUE -3 Uint8
1-66 Min. Current at Low Speed ExpressionLimit All set-ups TRUE 0 Uint8
1-7* Start Adjustments
1-70 PM Start Mode [1] Parking All set-ups TRUE - Uint8
1-71 Start Delay 00 s All set-ups TRUE -1 Uint16
1-72 Start Function ExpressionLimit All set-ups TRUE - Uint8
1-73 Flying Start ExpressionLimit All set-ups FALSE - Uint8
1-74 Start Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-75 Start Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-76 Start Current 0 A All set-ups TRUE -2 Uint32
1-77
Compressor Start Max Speed
[RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-78 Compressor Start Max Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-79
Compressor Start Max Time to
Trip 5 s All set-ups TRUE -1 Uint8
1-8* Stop Adjustments
1-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
1-81
Min Speed for Function at Stop
[RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-82
Min Speed for Function at Stop
[Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-86
Compressor Min. Speed for Trip
[RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-87
Compressor Min. Speed for Trip
[Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-9* Motor Temperature
1-90 Motor Thermal Protection ExpressionLimit All set-ups TRUE - Uint8
1-91 Motor External Fan [0] None All set-ups TRUE - Uint8
1-93 Thermistor Source [0] None All set-ups TRUE - Uint8
Table 4.4
4.1.4 2-** Brakes
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
2-0* DC-Brake
2-00 DC Hold/Preheat Current 50 % All set-ups TRUE 0 Uint8
2-01 DC Brake Current 50 % All set-ups TRUE 0 Uint16
2-02 DC Braking Time 10 s All set-ups TRUE -1 Uint16
2-03 DC Brake Cut In Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
2-04 DC Brake Cut In Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
2-06 Parking Current 50 % All set-ups TRUE 0 Uint16
2-07 Parking Time 3 s All set-ups TRUE -1 Uint16
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
170 MG16H102 - VLT
®
is a registered Danfoss trademark
44

Table of Contents

Other manuals for Danfoss VLT FC 103

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 103 and is the answer not in the manual?

Danfoss VLT FC 103 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 103
CategoryDC Drives
LanguageEnglish

Related product manuals