4.1.6 4-** Limits/Warnings
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
4-1* Motor Limits
4-10 Motor Speed Direction [0] Clockwise All set-ups FALSE - Uint8
4-11 Motor Speed Low Limit [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
4-12 Motor Speed Low Limit [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
4-13 Motor Speed High Limit [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
4-14 Motor Speed High Limit [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
4-16 Torque Limit Motor Mode 110 % All set-ups TRUE -1 Uint16
4-17 Torque Limit Generator Mode 100 % All set-ups TRUE -1 Uint16
4-18 Current Limit ExpressionLimit All set-ups TRUE -1 Uint32
4-19 Max Output Frequency ExpressionLimit All set-ups FALSE -1 Uint16
4-5* Adj. Warnings
4-50 Warning Current Low 0 A All set-ups TRUE -2 Uint32
4-51 Warning Current High ImaxVLT (P1637) All set-ups TRUE -2 Uint32
4-52 Warning Speed Low 0 RPM All set-ups TRUE 67 Uint16
4-53 Warning Speed High
outputSpeedHighLimit
(P413) All set-ups TRUE 67 Uint16
4-54 Warning Reference Low -999999 N/A All set-ups TRUE -3 Int32
4-55 Warning Reference High 999999 N/A All set-ups TRUE -3 Int32
4-56 Warning Feedback Low
-999999 ReferenceFeed-
backUnit All set-ups TRUE -3 Int32
4-57 Warning Feedback High
999999 ReferenceFeed-
backUnit All set-ups TRUE -3 Int32
4-58 Missing Motor Phase Function ExpressionLimit All set-ups TRUE - Uint8
4-6* Speed Bypass
4-60 Bypass Speed From [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
4-61 Bypass Speed From [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
4-62 Bypass Speed To [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
4-63 Bypass Speed To [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
4-64 Semi-Auto Bypass Set-up [0] Off All set-ups FALSE - Uint8
Table 4.7
4.1.7 5-** Digital In/Out
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
5-0* Digital I/O mode
5-00 Digital I/O Mode [0] PNP - Active at 24V All set-ups FALSE - Uint8
5-01 Terminal 27 Mode [0] Input All set-ups TRUE - Uint8
5-02 Terminal 29 Mode [0] Input All set-ups TRUE - Uint8
5-1* Digital Inputs
5-10 Terminal 18 Digital Input ExpressionLimit All set-ups TRUE - Uint8
5-11 Terminal 19 Digital Input ExpressionLimit All set-ups TRUE - Uint8
5-12 Terminal 27 Digital Input ExpressionLimit All set-ups TRUE - Uint8
5-13 Terminal 29 Digital Input ExpressionLimit All set-ups TRUE - Uint8
5-14 Terminal 32 Digital Input ExpressionLimit All set-ups TRUE - Uint8
5-15 Terminal 33 Digital Input ExpressionLimit All set-ups TRUE - Uint8
5-16 Terminal X30/2 Digital Input ExpressionLimit All set-ups TRUE - Uint8
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
172 MG16H102 - VLT
®
is a registered Danfoss trademark