System 9700 User Manual
Page 13 of 56
3. Operating instructions
This chapter outlines the procedure and precautions for operation in local and in remote control
mode. It identifies and describes the controls and indicators on the M-Panel Graphical. The
programming of the remote lines is also described. Instructions for initial remote line set up are
given in chapter 3.3.
3.1. Switching on
When precautions have been checked in accordance with chapters 2.3 and 2.4 the power
supply can be switched on.
If the M-Panel is connected:
Immediately after the power supply is switched on, a start-up screen appears on the M-Panel
and displays which control module is connected, and performs a self-diagnosis.
After approximately 5 s, the panel is ready for use. The remote line is ready for use after
approximately 3 s.
Make sure that the time between switching the control power OFF and ON again is at least 5 s
to ensure a correct cold start (initialization of the power supply).
1. Select LOCAL CONTROL mode at the CMD-menu. "LOC" text appears in the display (1).
To turn the power supply ON for the first time, it is recommended to activate it in LOCAL
CONTROL mode, as this is the easiest way to get started.
2. If any interlocks are set, push the "Reset" button (8). Remove the faults if the Interlocks do
not reset.
3. Set the desired output current by use of the SET-menu.
4. Switch the main power "ON" (3).
5. The READY LED (6) illuminates, when the output current is equal to the preset value within
a given accuracy, typically +/-200ppm.
6. Switch the main power "OFF" (5).