System 9700 User Manual
Page 7 of 56
COOLING
Water ...... 1 l/min @ max. Inlet temperature 35° C
Differential pressure ..................................... 1 bar
Test pressure ............................................. 15 bar
TEMPERATURE RATINGS
Operation Ambient temperature ............. 15 - 40° C
Storage temperature .. -20 - 70° C, non-condensing
CABINET LAY-OUT
Material ....................................................... Steel
Dimensions:
W x D x H .... 482 mm x 550 mm x nx132.5 (nx3U)
Mounting ........................................... 19-inch rack
Weight ............. n x 32 kg (shipping weight 35 kg)
NORMS
Immunity for industries ..... EN/IEC 61000-6-2:2005
Emission for industries ..... EN/IEC 61000-6-4:2007
Harmonic Emission
(single phase) ................... EN/IEC 61000-3-2:2006
Harmonic Emission
(three phase) ................ EN/IEC 61000-3-12:2014
Electromagnetic
compatibility ................... EN/IEC 61000-3-11:2000
Safety req. for