SD Series Installation and Administrator’s Guide 55
Changesettingsasneeded,andthenclickSetCurrenttoapplychanges.
CustomCharHigh—Specifythe numericvalueofthehighestASCIIcharacter
supportedforinputdataonthetrack.
CustomCharLength—Setthenumberofbitstorepresentonecharacterof
dataonthetrack,alsocalledbitspercharacter.
CustomCharLow—SpecifythenumericvalueofthelowestASCIIcharacter
supportedforinputdataonthetrack.
CustomCharMask—SpecifythemaskvaluethatissubtractedfromtheASCII
numericvaluetogettheencodedvalue.
CustomCharMax—Specifythemaximumnumberofdatacharactersforthe
track.Thevaluedoesnotincludethestartsentinelorendsentinel.
CustomDensity—Specif ythenumberofdatabitsperinchofmagneticstripe
mediaforthetrack,alsocalledbitsperinchorbpi.Allowedvaluesare75bpi
or210bpi.
CustomEndSentinel—Specifythelastcharacterencoded,whichidentifiesthe
endofencodeddataforthetrack.
CustomLrc—Specifyacumulativeparitybitthatisencodedaftertheend
sentineltoprovidesimpleerrorchecking.
CustomParity—Specifyacharacterlevelparitybitencodedaftereach
charactertoprovidesimpleerrorchecking.
CustomSdsNulls—Specifythenumberofnullsbetweeneachcopyofthedata
record.Youshouldnotchangethisvalue.
CustomSdsRecords—Specifythenumberoftimestoencodethedatarecord.
Youshouldnotchangethisvalue.
CustomSdsSs—Specifythenumberofstartsentinelsbeforeeachdatarecord.
Youshouldnotchangethisvalue.
CustomStartSentinel—Specifythefirstcharacterencoded,whichidentifies
thestartoftheencodeddataforthetrack.