DS2400
36
5
SOFTWARE FEATURES
READABLE CODE SYMBOLOGIES
EAN/UPC (including Add-on 2 and Add-on 5) Code 93
2/5 Interleaved Code 128
Code 39 (Standard and Full ASCII) EAN 128
Codabar Pharmacode
Other symbologies available on request.
Code Selection
up to six different codes during one reading phase
Decoding Safety
can enable multiple good reads of same code
Headers and Terminators
up to four headers and four terminators
Operating Modes
On-Line, Automatic, Serial-On-Line, Test
Configuration Modes
through menus using WinHost utility
receiving commands from one of the serial ports (HOST
MODE)
Parameter Storage
Non-volatile internal EEPROM
ENVIRONMENTAL FEATURES
Operating temperature
(Note 3)
0 to 40 °C (32 to 104 °F)
Storage temperature
-20 to 70 °C (-4 to 158 °F)
Humidity max. 90% non condensing
Vibration resistance IEC 68-2-6 test FC 1.5 mm;
10 to 55 Hz; 2 hours on each axis
Shock resistance IEC 68-2-27 test EA 30G;
11 ms; 3 shocks on each axis
Protection class IP65
PHYSICAL FEATURES
Mechanical dimensions 68 x 83.4 x 34 mm (2.7 x 3.28 x 1.3 in)
Weight 330 g. (11.64 oz.)
Note 1: The features given are typical at a 25 °C ambient temperature (if not otherwise
indicated).
Note 2: Further details given in par. 3.3.
Note 3: If the reader is used in high temperature environments (over 35 °C), use of the
Beam-shutter is advised (see the WinHost configuration program).