DS2400
18
2
5
3
USER INTERFACE
C.L. IN-
C.L. IN+
MAX. 300 METERS
I = 20 mA
4
C.L. OUT-
2
C.L. OUT+
I = 20 mA
DS2400
Figure 18 - 20 mA C.L. connections
2.4.3 Auxiliary RS232 Interface
The auxiliary serial interface is used exclusively for RS232 point to point connections.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as
particular operating modes such as LOCAL ECHO can be defined using the WinHost
utility program installed from the diskette or "Host Mode" programming provided on
diskette.
The following pins of the 25-pin connector are used to connect the RS232 auxiliary
interface:
Pin Name Function
20 RXAUX receive data
21 TXAUX transmit data
23 CTSAUX clear to send
24 RTSAUX request to send
7 SGND signal ground
7
SGND
SGND
TXD
RXAUX
20
RXD
TXAUX
21
DCD
RTSAUX
24
DTR
CTSAUX
23
Figure 19 - RS232 auxiliary interface connections using hardware handshaking