INDUSTRIAL 2 OF 5 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE   
175
Industrial 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for "Industrial 2 of 5 Length Control" on
page 174
. Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data
characters.
The length can be set from 1 to 50 characters. See "
Set Length 1" on page 297 for more
detailed programming instructions.
Industrial 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for "Industrial 2 of 5 Length Control" on
page 174
. Length 2 is the maximum label length if in Variable Length Mode, or the sec-
ond fixed length if in Fixed Length Mode. The length includes the bar code’s check and
data characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this
length (only one  fixed length). See  "
Set Length 2"  on page  298  for more detailed pro-
gramming instructions.
Select Industrial 2 of 5 Length 1 Setting
$CU2L1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
Length 1 = 06 (6 characters)
Select Industrial 2 of 5 Set Length 2 Setting
$CU2L2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)