ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
200
GRYPHON™ I GD/GBT/GM4500
Pharmacode Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Pharmacode symbology.
Variable Length: For variable-length decoding, a minimum length may be set.
Fixed Length: For fixed-length decoding, two different lengths may be set.
Pharmacode Set Length 1
This feature specifies one of the bar code lengths for "Pharmacode Length Control" on
page 200
. Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data
characters.
The length can be set from 2 to 6 characters. See "
Set Length 1" on page 297 for more
detailed programming instructions.
$CP1LC00
Pharmacode Length Control = Variable Length
Pharmacode Length Control = Fixed Length
$CP1LC01
Select Pharmacode Length 1 Setting
$CP1L1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 02 (two characters)