ENTER/EXIT PROGRAMMING MODE RS-232 INTERFACE
38
   GRYPHON™ I GD/GBT/GM4500
Data Bits
This  parameter  allows  the  reader  to  interface  with  devices  requiring  a  7-bit  or  8-bit
ASCII protocol for sending and receiving data.
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of transmission
of one character and prepares the receiving device for the next character in the serial
data stream. The number of stop bits selected (one or two) depends on the number the
receiving  terminal  is  programmed  to  accommodate.  Set  the  number  of  stop  bits  to
match host device requirements..
$CR2DA00
7 Data Bits
8 Data Bits
$CR2DA01
NOTE: Handheld and base station models support the 8-bit ASCII protocol.
The 7-bit ASCII protocol support is subject to specific firmware release.
If the setting is not supported, the reader will emit three short beeps upon
scanning the label.
$CR2ST00
1 Stop  Bit
2 Stop  Bits
$CR2ST01