PHARMACODE ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
199
PHARMACODE
The following options apply to the Pharmacode symbology.
Pharmacode Enable/Disable
Enables/Disables the ability of the reader to decode Pharmacode labels.
Pharmacode Label Direction
This feature specifies the direction in which labels are decoded.
$CP1EN00
Pharmacode = Disable
Pharmacode = Enable
$CP1EN01
$CP1DI00
Pharmacode Label Direction=
Horizontal left to right
Pharmacode Label Direction =
Horizontal right to left
$CP1DI01
$CP1DI02
Pharmacode Label Direction =
Vertical top down
Pharmacode Label Direction =
Vertical bottom up
$CP1DI03