OTHER KEYBOARD PARAMETERS ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE   
75
Wedge Quiet Interval
This option specifies the amount of time to look for keyboard activity before the reader
breaks the keyboard connection in order to transmit data to host. The selectable range
for this feature is from 0 to 990ms in 10ms increments. See "
Wedge Quiet Interval" on
page 278
 for more detailed programming instructions.
NOTE: This feature applies ONLY to the Keyboard Wedge interface.
Select Wegde Quiet Interval Setting
$CKBQI
To configure this feature, scan the ENTER/EXIT bar 
code above, then the bar code at left followed by dig-
its from the Alphanumeric characters in Appendix D, 
Keypad representing your desired character(s). End 
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
10 = Quiet Interval of 100 msec