126 Magellan
®
2200VS/2200VS and 2300HS/2300HS
RS-232 Number of Data Bits
Specifies number of data bits required for sending and receiving data.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code below representing the desired Data Bit setting.
You’ll need to cover any unused bar codes on this and the facing
page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
RS-232 NUMBER OF DATA BITS = 7
RS-232 NUMBER OF DATA BITS = 8
NOTE
8 data bits with 2 stop bits and parity enabled is not a valid configura-
tion.