406 Magellan
®
2200VS/2200VS and 2300HS/2300HS
Code 93
• Prefix must be ASCII characters ']G0'.
• Label length excluding prefix characters must meet requirements
imposed by the main scanner's fixed or variable label length control
for this symbology type.
• Example : ']G0Code93-test'.
DataBar Omnidirectional
• Prefix must be ASCII characters ']e0'.
• Check character must be included in label.
• Label length excluding prefix characters must be 14 characters.
• Example: ']e001044123456789'.
DataBar Expanded
• Prefix must be ASCII characters ']e0'.
• Label length excluding prefix characters must be at least 1 character.
Maximum length is the maximum label size supported by the scan-
ner.
• Example: ']e001900123456789083103001750'.
I 2 of 5
• Check character must be included in label data.
• Label length including check characters and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
• Prefix must be ASCII characters ']I0', ']I1' or ']I2' (other prefixes
specify different check character properties which are not sup-
ported).
• Example: ']I10123456789'.