78 Magellan
®
2200VS/2200VS and 2300HS/2300HS
Good Read When to Indicate
This feature specifies when the scanner will provide indication (beep and/
or flash its green LED) upon successfully reading a bar code.
Good Read = Indicate after decode
Good Read = Indicate after transmit
Good Read = Indicate after CTS goes inactive, then active
To set the Good Read When to Indicate feature:
1. Scan the SWITCH bar code.
2. Scan the desired mode bar code from this page. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
GOOD READ = INDICATE AFTER DECODE
NOTE
The “Indicate after CTS goes inactive...” mode applies to RS-232 STD
and RS-232 WN interfaces only. If set to this mode in other interfaces,
“Indicate after decode” mode will be implemented.