UPC/EAN GLOBAL SETTINGS ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
125
Optional Add-ons
The reader can be enabled to optionally read the following add-ons (supplementals):
P2
P5
NOTE: If a UPC/EAN base label and a an add-on are both decoded, the
reader will transmit the base label and add-on. If a UPC/EAN base label is
decoded without an add-on, the base label will be transmitted without an
add-on.
Conditional add-on settings (if enabled) are considered by the reader
before optional add-on settings.
$CADO200
Optional Add-Ons = Disable P2
Optional Add-Ons = Enable P2
$CADO201
$CADO500
Optional Add-Ons = Disable P5
Optional Add-Ons = Enable P5
$CADO501