As  with  other  types  of  batteries,  Lithium-Ion  (LI)  batteries  will  lose  capacity  over  time.
Capacity deterioration is noticeable after one year of service whether the battery is in use
or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers
rate them at 500 charge cycles. In other words, the batteries should be expected to take
500 full  discharge /  charge cycles before needing  replacement. This  number is  higher  if
partial discharging / recharging is adhered to rather than full / deep discharging, 
The  typical  manufacturer  advertised  useful  life  of  LI  batteries  is  one  to  three  years,
depending  on  usage  and  number  of  charges,  etc., after  which  they  should  be  removed
from service, especially in mission critical applications. Do not continue to use a battery
that is showing excessive loss of capacity, it should be properly recycled / disposed of and
replaced. For most applications, batteries should be replaced after one year of service to
maintain customer satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in compliance with Euro-
pean Directive 2006/66/EC, 2011/65/EU, 2002/96/EC and 2012/19/EU and subsequent mod-
ifications,  US  and  China  regulatory  and  others  laws  and  regulations  about  the
environment.
PROGRAMMING THE READER
Configuration Methods
Programming Bar Codes
The reader is factory-configured with a standard set of default features. After scanning the
interface bar code, you can select other options and customize your reader through use of
the instructions and programming bar code labels available in the corresponding features
section for your interface. Customizable settings for many features are found in 
Configura-
tion Parameters, starting on page 34
.
Some programming labels, like “Restore Custom Defaults”, require only the scan of the sin-
gle label to enact the change. Most, however, require the reader to be placed in Program-
ming  Mode  prior  to  scanning  them.  Scan  an  ENTER/EXIT  bar  code  once  to  enter
Programming Mode. Once the reader is in Programming Mode, scan a number of parame-
ter  settings  before  scanning  the  ENTER/EXIT  bar  code  a  second  time,  which  will  then
accept your changes, exit Programming Mode and return the reader to normal operation.
Datalogic Aladdin™
Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-friendly
configuration method via the RS-232/USB-COM interface. Aladdin allows you to program
the reader by selecting configuration commands through a user-friendly graphical inter-
face running on a PC. These commands are sent to the reader over the selected communi-
cation interface, or they can be printed as bar codes to be scanned. Aladdin also facilitates
image capturing.
In addition, Aladdin makes it easy to upgrade the handheld’s firmware, to attain the bene-
fits of new reader features. Reference the Datalogic Aladdin™ Online Help for more details.
Aladdin is available for download free of charge on the Datalogic website.
CAUTION: Only in case of long storage, to avoid deep discharge of the battery it
is recommended to partially recharge the battery every three months to keep
the charge status at a medium level.
As  a  reference,  run  a  fast  recharge  for  20  minutes  every  three  months  on
unused products to avoid any performance deterioration of the cell.
NOTE:  There  are  some  exceptions  to  the  typical  programming  sequence
described above. Please read the description and setting instructions care-
fully when configuring each programmable feature.