Enter/Exit Programming Mode Code 39
138
Touch TD1100
Code 39 Set Length 1
This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the
minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters.
The length can be set from 0 to 50 characters. See "Set Length 1" on page 278 for more detailed
programming instructions.
$CC3L1
Select Code 39 Set Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from the
Alphanumeric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the begin-
ning.
~
CANCEL
DEFAULT
02 = Length 1 is 2 Characters