Enter/Exit Programming Mode LED and Beeper Indicators
74
Touch TD1100
Good Read: When to Indicate
This feature specifies when the reader will provide indication (beep and/or flash its green LED)
upon successfully reading a bar code. Choices are:
Good Read = Indicate after decode
Good Read = Indicate after transmit
Good Read = Indicate after CTS goes inactive, then activ
NOTE
This option, which uses CTS, is only valid for RS-232 interfaces.
e
$CBPIN00
Indicate Good Read = After Decode
$CBPIN01
Indicate Good Read = After Transmit
$CBPIN02
Indicate Good Read = After CTS Goes Inactive, Then
Active