Scanning Features References
Product Reference Guide  
          277
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable 
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with 
leading 
ze
roes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming 
Mode
.
4. Scan the bar code: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in 
Appendix D, Keypad
, that represent the 
duration which was determined in the steps above. Y
ou will hear a two-beep indication 
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code 
to abort and not save the entry string. You can then start again at the 
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming 
Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 20. Flash Off Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1,000ms (1 sec.)
5200ms (5.2 
sec.)
9,
900ms (9.9 sec.)
2
Divide by 100 (and pad with 
leading zero
es to yield two 
digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From 
Appendix D, Keypad
 ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’  ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE