Datalogic 2 of 5 Enter/Exit Programming Mode
Product Reference Guide  
          169
Datalogic 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control. Length 1 
is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed 
Length Mode. The length includes the bar code’s data characters only.
The length can be set from 2 to 50 characters in increments of two. See "Set Length 1" on 
page 278 for more detailed programming instructions.
$CD2L1
Select Datalogic 2 of 5 Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar code 
above, then the bar code at left followed by digits from the 
Alphanumeric characters in 
Appendix D, Keypad
 repre-
senting your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not 
save the entry string. You can then start again at the begin-
ning.
~
CANCEL
DEFAULT
06 = Length 1 is 6 Characters