3 | Connections and Setup
Workstation Series User’s Guide 20
2. Close and latch the printer cover.
3. Select the Stop/Resume button and the Feed/Cancel button together with long
presses until the paper begins to move.
Note: The media will advance through the printer verifying the top-of-form.
Sensor Calibration
Sensor calibration is set during the manufacturing process and may only need to be
performed after upgrading the printers software or resetting defaults. This is indicated by
the red LED blinking slowly after power-up.
1. Remove the paper from the printer.
2. Close and latch the printer cover.
3. Push the Reset, Stop/Resume, and the Feed/Cancel buttons together with one long
press.
Note: Wait for the green LED to fast blink followed by solid green.
Printer Settings
All printer settings can be adjusted in the configuration utility or the printer’s internal web
pages. Refer to the Help section in the utility for more information.