AP25 Installation and Operating Guide Version 1.00
Appendix H. Serial Command AP! H-4 Document #: 9301H79500 Ver. 1.00
t3: H335 board temperature
Example response:
HEALTH TEMPERATURE 34,29,25
H331VOLTS
Returns voltages sensed on H331 board,
<vok>,<ref>,<5v>,<+15v>,<-15v>,<-5V>
Example response:
HEALTH H331VOLTS 1,3.18,4.99,15.0,-15.0-,-5.0
<vok> is 1 if voltages are all within limits, else 0
H332VOLTS
Returns voltages sensed on H332 board,
<vok>,<ref>,<5v>,<+15v>,<-15v>,<-5V>
Example response:
HEALTH H332VOLTS 1,3.18,4.99,15.0,-15.0-,-5.0
<vok> is 1 if voltages are all within limits, else 0.
If H332 board is not present, response will be
HEALTH H332VOLTS NA
H335VOLTS
Returns voltages sensed on H335 board, <vok>,<ref>,<1.3v>
Example response:
HEALTH H335VOLTS 1,3.13,1.32
<vok> is 1 if voltages are all within limits, else 0
H336VOLTS
Returns voltages sensed on H336 board,
<vok>,<ref>,<+5V>,<+15V>,<-15V>,<48V>,<vcpu>
Example response:
HEALTH H336VOLTS 1,3.39,5.10,15.0,-14.4,0.0,1
<vok> is 1 if voltages are all within limits, else 0
<48V> is mic phantom power, will be 0 if phantom power off
<vcpu> will be 1 if CPU power in limits, else 0
H338VOLTS
Returns voltages sensed on H338 board,
<vok>,<ref>,<5v>,<+10V>,<-10V>
Example response:
HEALTH H338VOLTS 0,3.18,5.02,10.56,-10.48
<vok> is 1 if voltages are all within limits, else 0
If H338 board is not present, response will be:
HEALTH H338VOLTS NA