G3
™
User’s & Installation Manual
7/October/2020
72
Appendix B: Communications Port - serial protocols.
G3™ COM X serial outputs selections:
COMX setting Output
0 No output
1 Diagnostic output
2 Linear spectrum output
3 Future expansion
4 Future expansion
5 Future expansion
6 Future expansion
7 G3™ standard output
8 COPS (Common Output Protocol) Please contact
your local sales or service agent for protocol
description.
9 Power dB spectrum output
G3™ Standard Output:
The standard serial communication has the following characteristics
(8N1) and is transmit only:
• One(1)startbit
• Eight(8)databits
• Noparity
• One(1)stopbit
• Transmissionat1200baud
The G3™ transmits data as ASCII symbols in the following digit
sequence:
Target Patrol
[hundreds][tens][ones] [hundreds][tens][ones]<CR>
(<CR> = ASCII decimal value 13)
The G3™ sends the data in this sequence when the TARGET or PATROL
speed display changes, or when the MODE or antenna selection
changes. During the test sequence the target and patrol speeds
transmit, but the display segment check data do not.
When you press the LOCK button, the G3™ transmits the following
digital sequence: [hundreds][tens][ones]<CR> (<CR> = ASCII
decimal value 13)