V0208, 2.24
Range : 1 - 100
Unit : %
Default : 80
Remark
Only if ‘Control type’ (19) is set to 2.
Function
This is the output voltage for high speed movement in the negative direction. This parameter
must be programmed if a 2-speed DC motor drive is controlled with the analog output. It is
programmed as a percentage of the maximum output voltage (10 V).
Parameter 64
DC high speed >
Range : 1 - 100
Unit : %
Default : 80
Remark
Only if ‘Control type’ (19) is set to 2.
Function
This is the output voltage for high speed movement in the positive direction. This parameter
must be programmed if a 2-speed DC motor drive is controlled with the analog output. It is
programmed as a percentage of the maximum output voltage (10 V).
Parameter 65
Acceleration ramp
Range : 5 - 9999
Unit : msec
Default : 5
Remark
Only if ‘Control type’ (19) is set to 1 or 2.
Function
The nominal acceleration time, in which the axis accelerates from low speed to high speed.
This parameter must be programmed if 2-speed DC motor drives are used.
Parameter 66
Braking ramp
Range : 5 - 9999
Unit : msec
Default : 5
Remark