Delem
V0208, 2.23
Switch point from high speed to low speed in the upcounting direction.
Parameter 60
Stop time
Range : 0 - 9999
Unit : msec
Default : 0
Remark
Only if ‘Control type’ (19) is set to 1 or 2.
If ‘AC brake enabled’ (54) is set to 1, this parameter is not available.
Function
Delay time before switching off low speed after Brake point low speed (54/55) has been
reached.
Parameter 61
DC low speed <
Range : 1 - 100
Unit : %
Default : 4
Remark
Only if ‘Control type’ (19) is set to 1 or 2.
Function
This is the output voltage for low speed movement in the negative direction. This parameter
must be programmed if a DC motor drive is controlled with the analog output. It is
programmed as a percentage of the maximum output voltage (10 V).
Parameter 62
DC low speed >
Range : 1 - 100
Unit : %
Default : 4
Remark
Only if ‘Control type’ (19) is set to 1 or 2.
Function
This is the output voltage for low speed movement in the positive direction. This parameter
must be programmed if a DC motor drive is controlled with the analog output. It is
programmed as a percentage of the maximum output voltage (10 V).
Parameter 63
DC high speed <