Gap: program a known gap value for the blade.
AD-value: program the required feedback voltage for this gap. The voltage must be
programmed in the range 0-4095, it will be converted to an input voltage in the range 0-10V.
The adjustment procedure to find the correct AD-values is similar to the procedure for angle
values as described in the previous section.
Parameter 80
Gap material table
Range : -
Unit : -
Default : -
Function
Press ENTER to open a screen with the gap material table.
In this table the gap can be programmed as a function of sheet thickness and sheet material.
If this table is programmed, the gap is precomputed for each cutting step in a program.