Delem
V0208, 2.39
Parameter 107
Clamping force delay
Range : 0 - 999
Unit : msec
Default : 0
Function
After the ‘ST’ input goes low, the control will start force control. This parameter can be used to
program a delay before force control is started.
Parameter 108
Clamping reference table
Range : -
Unit : -
Default : -
Function
Press ENTER to open a screen with the Clamping reference table. In this table, the relation
between clamping force and control output voltage can be programmed.
Cut: program a known force value (in kiloNewtons) for a cut.
DA-value: program the required output voltage for this force. The output voltage must be
programmed in the range 0-4095, it will be converted to an output voltage in the range 0-10V.