EasyManua.ls Logo

Dell EMC DP4400 - NVMe card replacement

Dell EMC DP4400
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Verify that the status information for the NIC matches the information shown in the
example output.
Remove and replace the NVMe card
The NVMe card is not hot-swappable and requires a system shutdown.
The NVMe card in PCIe slot 4 is used as the SSD cache tier for the Data Domain Virtual Edition
(DDVE) VM. When you replace the NVMe card, you must reconfigure the DDVE cache tier.
Record existing SSD cache tier details
You will need the size and device number of the cache tier when you create the new data store
after replacing the NVMe card.
Procedure
1. Log in to the ACM GUI dashboard and determine the IP address for the DDVE VM.
2. Using SSH, log in to the DDVE VM as sysadmin using the common password for the
appliance.
3. To view the cache tier details, type the following command: # storage show tier
cache
sysadmin@ssg242172# storage show tier cache
Cache tier details:
Device Device Device
Group Size
------ ------ ---------
dg1 3 960.0 GiB
------ ------ ---------
Spindle Devices Count Total Size
Group
------- ------- ----- ----------
1 3 1 960.0 GiB
------- ------- ----- ----------
Current cache tier size: 0.9 TiB
Storage addable devices:
Device Device Device
Type Size
--------- ------ -------
(unknown) 14 4.1 TiB
(unknown) 15 4.1 TiB
(unknown) 16 4.1 TiB
(unknown) 17 4.1 TiB
(unknown) 26 4.1 TiB
Remove and replace assemblies
Dell EMC Integrated Data Protection Appliance DP4400 Service Procedures 71

Table of Contents

Other manuals for Dell EMC DP4400

Related product manuals