Figure 27. Installing a cooling fan
Next step
1 Follow the procedure that is listed in After working inside your system.
Optional internal USB memory key
An optional USB memory key installed inside your system can be used as a boot device, security key, or mass storage device. To boot from
the USB memory key, congure the USB memory key with a boot image and then specify the USB memory key in the boot sequence in
System Setup.
An optional USB memory key can be installed in the internal USB 3.0 port.
NOTE
: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Replacing the optional internal USB memory key
Prerequisites
CAUTION
: To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory
key: 15.9 mm width x 57.15 mm length x 7.9 mm height.
1 Follow the safety guidelines listed in the Safety instructions.
2 Follow the procedure listed in the Before working inside your system.
Steps
1 Locate the USB port or USB memory key on the system board.
To locate the USB port, see the System board jumper and connectors section.
2 If installed, remove the USB memory key from the USB port.
3 Insert the replacement USB memory key into the USB port.
58