NOTE: The procedure to remove the BOSS card is similar to the removing an expansion card.
Steps
1 Align the M.2 SSD module at an angle with the BOSS card connector.
2 Insert the M.2 SSD module until it is rmly seated in the BOSS card connector.
3 Using the Phillips #1 screwdriver, secure the M.2 SSD module on the BOSS card with the screw.
Figure 37. Installing the M.2 SSD module
Next steps
1 Install the BOSS card.
NOTE
: The procedure to install the BOSS card is similar to removing an expansion card.
2 Follow the procedure listed in the After working inside your system.
Processor and heat sink
Removing the heat sink module
Prerequisites
WARNING
: The heat sink may be hot to touch for some time after the system has been powered o. Allow the heat sink to cool
before removing it.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure that is listed in Before working inside your system.
Steps
1 Disconnect the heat sink fan power cable connector from the connector on the system board.
2 Using a Phillips #2 screwdriver, loosen the screws on the heat sink in the order following:
a Partially loosen the rst screw (approximately 3 turns).
Installing and removing system components
67