Converting the system from tower mode to rack mode
Your system can be converted from the tower mode to the rack mode.
To convert your system from the tower mode to the rack mode, you require the tower to rack conversion kit, which contains the following:
Rack ears (left and right) with three screws each
VGA module
VGA cable
Rack slide cover
Mylar cover
Converting the system from tower mode to rack mode
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Lay the system on a at, stable surface.
4 Remove the system cover.
5 If installed, remove the system feet or caster wheels.
Steps
1 Remove the system top cover.
2 Remove the control-panel assembly.
3 Install the rack slide cover by performing the following steps:
a Slide the rack slide cover between the system's side cover and the chassis.
b Slide the rack slide cover toward the back of the system until the tabs on rack slide cover locks with the tabs extending from the
chassis.
Figure 114. Installing the rack slide cover
4 Install the control panel assembly.
5 Attach the mylar to cover the screw hole on the chassis where one of the system rear feet was installed while in the tower mode.