Table 11. PSU specications
PSU Class Heat dissipation
(maximum)
Frequency Voltage Current
495 W AC Platinum 1908 BTU/hr 50/60 Hz 100–240 V AC, autoranging 6.5 A–3 A
750 W AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC, autoranging 10 A–5 A
750 W AC Titanium 2843 BTU/hr 50/60 Hz 200–240 V AC, autoranging 5 A
750 W Mix Mode Platinum 2891 BTU/hr 50/60 Hz 100-200 V AC, autoranging 10-5A
750 W Mix Mode Platinum 2891 BTU/hr 50/60 Hz 240 V DC, autoranging 4.5A
1100 W AC Platinum 4100 BTU/hr 50/60 Hz 100–240 V AC, autoranging 12 A–6.5 A
1100 W DC Gold 4416 BTU/hr - –(48–60) V DC, autoranging 32 A
1600 W AC Platinum 6000 BTU/hr 50/60 Hz 100–240 V AC, autoranging 10 A
2000 W Mix Mode Platinum 7500 BTU/hr 50/60 Hz 100–200 V AC, autoranging 11.5 A
2000 W Mix Mode Platinum 7500 BTU/hr 50/60 Hz 240 V AC, autoranging 11.8 A
2400 W AC Platinum 9000 BTU/hr 50/60 Hz 100–240 V AC, autoranging 16 A
NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
NOTE: If a system with 2400 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1400 W.
NOTE: If a system with 2000 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1000 W.
NOTE: If a system with 1600 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 800 W.
NOTE: If a system with 1100 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1050 W.
System battery specications
The Dell EMC PowerEdge T640 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion bus specications
The Dell EMC PowerEdge T640 system supports PCI express (PCIe) generation 3 and 2 expansion cards. The following table describes the
supported expansion cards:
Table 12. Supported PCI express generation 3 expansion cards
PCIe Slot Processor
Connection
Height Length Link Width Slot Width
0 (Internal
PERC/HBA Slot)
Processor 1 Full Height Half Length x8 x8
1 (Gen3) Processor 1 Full Height Full Length x16 x16
2 (Gen3) Processor 1 Full Height Full Length x4 x8
3 (Gen3) Processor 1 Full Height Full Length x16 x16
4 (Gen3) Processor 2 Full Height Half Length x8 x8