EasyManua.ls Logo

Dell EMC PowerEdge T640 - Removing the Right External Fan

Dell EMC PowerEdge T640
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 48. Installing a middle cooling fan
Next step
1 Follow the procedure listed in After working inside your system.
Removing the right external fan
Prerequisites
WARNING
: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise
utmost care while removing or installing cooling fans.
NOTE: The procedure to remove the left external fan is similar to removing the right rear fan.
1 Follow the safety guidelines listed in Safety instructions.
2 Remove the GPU air shrouds.
3 Remove the air shroud.
Steps
1 Disconnect the fan cable from the system board.
2 Using the Phillips #2 screwdriver, loosen the captive screws that secure the fan to the system.
3 Lift the fan away, while guiding the fan cable through the cable vent.
96
Installing and removing system components

Table of Contents

Other manuals for Dell EMC PowerEdge T640