Listed below are the restrictions for fan redundancy:
• GPGPU congurations are not supported at 35deg. C of ambient or above.
• Mellanox 100G NICs are not supported.
For information on the restriction for fresh air condition, see the Expanded operating temperature restrictions topic in the Technical
Specication section.
Cooling fan matrix
Table 32. Cooling fan matrix
Chassis FAN1, FAN2 (Standard
[STD])
FAN3, FAN4, FAN5,
FAN6 (Standard [STD]/
High performance
[HPR])
FAN_EXT_R,
FAN_EXT_L
Fan conguration
3.5 inch x 8 Yes - - Base conguration
3.5 inch x 18 Yes Yes (STD) - Rich conguration
2.5 inch x 16 Yes - - Base conguration
2.5 inch x 32 Yes - - Base conguration
2.5 inch x 16 + NVMe Yes Yes (STD) - Rich conguration
Fan redundancy, FA and
high cooling tier PCIe
card
Yes Yes (STD) - Rich conguration
GPGPU card Yes Yes (HPR) Yes GPU conguration
Removing a middle or rear cooling fan
The procedure for removing a standard and a high performance fans is identical.
Prerequisites
WARNING
: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise
utmost care while removing or installing cooling fans.
CAUTION: The cooling fans are hot swappable. To maintain proper cooling while the system is on, replace only one fan at a time.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Step
Press the release tab and lift the cooling fan out of the cooling fan assembly.