EasyManua.ls Logo

Dell EMC VxFlex Ready Node - Query GUID Using Drv_Cfg; Query Mdms Using Drv_Cfg

Dell EMC VxFlex Ready Node
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Example
/opt/emc/scaleio/sdc/bin/drv_cfg --query_tgts
Query GUID using drv_cfg
Command
drv_cfg --query_guid
Note:
This is not a CLI command, but rather an executable that is run on the SDC server.
Syntax
/opt/emc/scaleio/sdc/bin/drv_cfg --query_guid
Description/Notes
This utility retrieves the unique ID of the kernel module. The utility can be used to
verify that all SDC GUIDs in the system are unique.
Location of drv_cfg command:
l
Linux: /opt/emc/scaleio/sdc/bin/drv_cfg
l
Windows: C:\Program Files\emc\scaleio\sdc\bin\drv_cfg
l
ESXi: Refer to "Update the SDC parameters in VMware based HCI or Compute
node".
Note:
If the SDC was removed and reinstalled, the GUID of the SDC will be different to
its original GUID. In such a case, you may need to remove the SDC, if two SDCs
now have the same GUID.
Example
/opt/emc/scaleio/sdc/bin/drv_cfg --query_guid
Query MDMs using drv_cfg
Command
drv_cfg --query_mdms
Note:
This is not a CLI command, but rather an executable that is run on the SDC server.
Syntax
/opt/emc/scaleio/sdc/bin/drv_cfg --query_mdms
Managing System Objects
Dell EMC VxFlex Ready Node AMS User Guide 147

Table of Contents

Other manuals for Dell EMC VxFlex Ready Node

Related product manuals