Example
/opt/emc/scaleio/sdc/bin/drv_cfg --query_tgts
Query GUID using drv_cfg
Command
drv_cfg --query_guid
Note:
This is not a CLI command, but rather an executable that is run on the SDC server.
Syntax
/opt/emc/scaleio/sdc/bin/drv_cfg --query_guid
Description/Notes
This utility retrieves the unique ID of the kernel module. The utility can be used to
verify that all SDC GUIDs in the system are unique.
Location of drv_cfg command:
l
Linux: /opt/emc/scaleio/sdc/bin/drv_cfg
l
Windows: C:\Program Files\emc\scaleio\sdc\bin\drv_cfg
l
ESXi: Refer to "Update the SDC parameters in VMware based HCI or Compute
node".
Note:
If the SDC was removed and reinstalled, the GUID of the SDC will be different to
its original GUID. In such a case, you may need to remove the SDC, if two SDCs
now have the same GUID.
Example
/opt/emc/scaleio/sdc/bin/drv_cfg --query_guid
Query MDMs using drv_cfg
Command
drv_cfg --query_mdms
Note:
This is not a CLI command, but rather an executable that is run on the SDC server.
Syntax
/opt/emc/scaleio/sdc/bin/drv_cfg --query_mdms
Managing System Objects
Dell EMC VxFlex Ready Node AMS User Guide 147