EasyManua.ls Logo

Dell EMC VxFlex Ready Node - Page 289

Dell EMC VxFlex Ready Node
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Description
Description Capacity is critical, due to capacity used by
snapshots/thin volumes
Action Remove unnecessary snapshots or add more
storage
Device capacity has returned to normal
Parameter Description
Name DEV_CAPACITY_USAGE_NORMAL
Message Capacity usage on %s is normal.")
Severity Info
Description Capacity usage is back to normal
Action Not needed
SDS configuration has become invalid
Parameter
Description
Name SDS_CONFIG_INVALID
Message CLI_TARGET_NAME_CAP" %s (ID
"MOS_OBJID__FORMAT ") configuration is
invalid.
Severity Critical
Description The SDS cannot access its configuration files.
Action Contact EMC Support
SDS disk errors were fixed
Parameter
Description
Name SDS_FIX_DISK_ERROR
Message CLI_TARGET_NAME_CAP" %s (ID
"MOS_OBJID__FORMAT ") device %s fixed
%d disk errors via reads.
Severity Warning
Description There were read errors on this device that
were fixed by reading the data from
secondary and re-writing it. This may be a
sign of impending device hardware
malfunction.
Action Check for hardware malfunction
System events
Dell EMC VxFlex Ready Node AMS User Guide 289