Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
Physical Disk state
is erroneous (Hot
Spare)
PHYSICAL_DRIVE_
HOT_SPARE
Storage_Controller.
Physical_Drive.HOT
_SPARE
SIO06.01.000
0002
3 (Error) Errors have been detected on
a spare Physical Disk.
Replace the Physical Disk.
The Physical Disk is
not being used by
the system
PHYSICAL_DRIVE_
NOT_IN_USE
Storage_Controller.
Physical_Drive.NOT
_IN_USE
SIO06.01.000
0003
3 (Error) Access the storage controller
and configure the disk.
SSD lifespan is over
endurance threshold
PHYSICAL_DRIVE_
ENDURANCE_USE
D_ABOVE_THRESH
OLD
Storage_Controller.
Physical_Drive.Endu
rance_Used_Above
_Threshold
SIO06.01.000
0004
5 (Critical) Replace the SSD device.
The Physical Disk
temperature has
exceeded the
configured
threshold
PHYSICAL_DRIVE_I
NVALID_TEMPERA
TURE
Storage_Controller.
Physical_Drive.INVA
LID_TEMPERATUR
E
SIO06.01.000
0005
5 (Critical)
3 (Error)
Ensure that the server and its
environment are properly
cooled. Ensure that the
internal chassis fans are
working, and that there is
adequate airflow.
The Physical Drive's
cache is not disabled
PHYSICAL_DRIVE_I
NVALID_PD_CACH
E_POLICY
Storage_Controller.
Physical_Drive.INVA
LID_PD_CACHE_P
OLICY
SIO06.01.000
0006
3 (Error) Disable the Physical Drive
physical cache. Note: This
may cause DI issues in power
cycle scenarios.
Device was
requested to use as
DAS Cache but it is
not
DEVICE_SHOULD_
USE_AS_DAS_CAC
HE_BUT_IT_IS_NO
T
Storage_Controller.
Physical_Drive.Devi
ce_Should_Use_As
_Das_Cache_But_It
_Is_Not
SIO06.01.000
0007
3 (Error)
The Logical Disk
read policy is not set
to "Read-Ahead"
LOGICAL_DISK_INV
ALID_READ_AHEAD
_POLICY
Storage_Controller.
Logical_Disk.INVALI
D_READ_AHEAD_P
OLICY
SIO06.02.000
0001
3 (Error) Access the storage controller
and change the Logical Disk's
read policy to "Read Ahead".
The Logical Disk IO
policy is not
Configured properly
(Write-Back)
LOGICAL_DISK_INV
ALID_WRITE_BACK
_POLICY
Storage_Controller.
Logical_Disk.INVALI
D_WRITE_BACK_P
OLICY
SIO06.02.000
0002
3 (Error) Check the Raid controller
battery status, a fault in the
battery will impact the Write-
Back functionality.
Logical Disk access
mode is not set to
"Read-Write"
LOGICAL_DISK_INV
ALID_ACCESS_MO
DE
Storage_Controller.
Logical_Disk.INVALI
D_ACCESS_MODE
SIO06.02.000
0003
5 (Critical) Access the storage controller
and change the logical disk's
access mode to "Read-
Write".
The Logical Disk
RAID level is not set
to RAID0
LOGICAL_DISK_INV
ALID_RAID_LEVEL
Storage_Controller.
Logical_Disk.INVALI
D_RAID_LEVEL
SIO06.02.000
0004
3 (Error) The RAID type is set in the
storage controller is
incorrect. Access the storage
controller, verify that the
Logical Disk does not contain
any data that is not backed-
up, destroy the Logical Disk,
SNMP Trap Support