Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
higher than the
configured
threshold
CPU and internal chassis fans
are active.
The CPU Voltage
Regulator's voltage
is not within the
configured
threshold
CPU_SOCKET_INV
ALID_VR_VOLTAGE
Node.Cpu_Socket.I
NVALID_VR_VOLTA
GE
SIO07.03.000
0006
5 (Critical)
3 (Error)
1. Verify that the power
supply is functioning
correctly. 2. Try to replace a
port in the Power Distribution
Unit, or supply an external
power source to check it. 3.
Replace the power cable. 4.
Replace the Power Supply
Unit module.
CPU has invalid
voltage state state
CPU_SOCKET_INV
ALID_VOLTAGE
Node.Cpu_Socket.I
nvalid_Voltage
SIO07.03.000
0007
5 (Critical) Check the chassis power
supply
RAM temperature is
not within threshold
RAM_INVALID_TE
MPERATURE
Node.Ram.Invalid_T
emperature
SIO07.04.000
0001
5 (Critical)
3 (Error)
The temperature of one or
more Server RAM modules
exceeds the configured
threshold. Ensure that the
server and its environment
are properly cooled and that
all the chassis fans are
functional.
RAM voltage
regulator's
temperature is not
within threshold
RAM_INVALID_VR_
TEMPERATURE
Node.Ram.INVALID
_VR_TEMPERATUR
E
SIO07.04.000
0002
5 (Critical)
3 (Error)
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional.
RAM voltage
regulator's voltage
is not within
threshold
RAM_INVALID_VR_
VOLTAGE
Node.Ram.INVALID
_VR_VOLTAGE
SIO07.04.000
0003
5 (Critical)
3 (Error)
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional. If
the system still issues an
alert, the DIMM may be
faulty, and may have to be
replaced.
The node
temperature has
exceeded the
configured
threshold
NODE_INVALID_TE
MPERATURE
Node.Node.INVALID
_TEMPERATURE
SIO07.05.000
0001
5 (Critical)
3 (Error)
Ensure that the server and its
environment are properly
cooled and that all the
chassis fans are functional.
The voltage values
on the node are not
within the
configured
threshold
NODE_INVALID_VO
LTAGE
Node.Node.INVALID
_VOLTAGE
SIO07.05.000
0002
5 (Critical)
3 (Error)
1. Verify that the power
supply is functioning
correctly, and then try to
replace a port in the Power
Distribution Unit or check
with external power. 2.
SNMP Trap Support
316 Dell EMC VxFlex Ready Node AMS User Guide