Deploying FCoE (FIP Snooping) on Dell Force 10 MXL
63
o feature FCOE enables the feature for FCOE as long as the licensing and FC modules are
installed.
o slot 2 enter into the slot 2 configuration
o port 15-16 type fc at slot 2 port 15-16 set the unified ports to be type FC
o vlan 20 this is the VLAN to be used for the Native VLAN.
o vlan 1000 - this is the VLAN being used for FCoE in this example
fcoe vsan 2 this establishes the previous VLAN 1000 as an FCoE VLAN in VSAN 2.
o vsan database enter into the vsan database interface.
vsan 2 initializes VSAN 2
vsan 2 interface vfc1 set interface vfc1 to be part of VSAN 2
vsan 2 interface fc2/15 set interface fc2/15 to be part of VSAN 2
o interface vfc1 selects virtual fc interface vfc1 (vfc1 is an example and can be a different
number based on the admin’s choice at configuration time).
bind interface port-channel20 this binds interface Ethernet 1/1 to the virtual fc
interface which in this case is vfc1. This is one form of binding the VFC. The other form
would be to bind the VFC to the FCoE FIP MAC address of the CNA being used. Examples
of this will be included later in the document.
no shutdown turns the virtual interface on since default is shutdown.
o interface fc2/15 selects the fc2/15 interface (which will typically be the first fibre channel
port on the Nexus 5020.
no shutdown turns the fc2/15 interface on since default is shutdown.
o interface Ethernet 1/1 selects interface Ethernet 1/1
switchport mode trunk set switchport mode to trunk for the 2 VLAN’s.
switchport trunk allowed vlan 1000 add allowed VLAN 1000 to the trunk.
o zone name blade1 vsan 2 this will set the name for your zone (blade1 can be any chosen
name); vsan 2 will match the vsan you have created.
member interface fc2/15 - this adds the fc2/15 interface as a member of the zone.
member pwwn xx:xx:xx:xx:xx:xx:xx:xx adds the port WWN of the ENode device to
the zone. (insert the port WWN of the device being used).
o zoneset name set1 vsan 2 move into the zoneset interface (in this case the name is set1 but
could be any name and the VSAN number is based on the FCoE VLAN being used.
member blade1 this includes the blade1 zone into this zoneset.
o zoneset activate name set1 vsan 2 activates the zoneset containing these zones.

Table of Contents

Other manuals for Dell Force10 MXL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Force10 MXL and is the answer not in the manual?

Dell Force10 MXL Specifications

General IconGeneral
ManageableYes
Product SeriesForce10 MXL
Operating Temperature0°C to 40°C (32°F to 104°F)
Layer SupportLayer 2, Layer 3
QoS SupportYes
Power SupplyDual, hot-swappable
Product TypeSwitch
Jumbo Frame SupportUp to 9216 bytes
ManagementCLI, SNMP, Web-based GUI
VLAN SupportYes