Deploying FCoE (FIP Snooping) on Dell Force 10 MXL
86
switchport trunk allowed vlan 11-12
vpc 11
interface port-channel12
switchport mode trunk
switchport trunk allowed vlan 11-12
vpc 12
interface port-channel20
switchport mode trunk
switchport trunk native vlan 20
switchport trunk allowed vlan 20,1000
interface port-channel500
switchport mode trunk
spanning-tree port type network
vpc peer-link
interface vfc2
bind interface port-channel20
no shutdown
vsan database
vsan 2 interface vfc2
vsan 2 interface fc1/31
vsan 2 interface fc1/32
interface fc1/31
no shutdown
interface fc1/32
no shutdown
interface Ethernet1/1
switchport mode trunk
switchport trunk allowed vlan 11-12
channel-group 11 mode active
interface Ethernet1/2
switchport mode trunk
switchport trunk allowed vlan 11-12
channel-group 11 mode active
interface Ethernet1/3
interface Ethernet1/4
interface Ethernet1/5
switchport mode trunk
switchport trunk native vlan 20
switchport trunk allowed vlan 20,1000
channel-group 20 mode active
interface Ethernet1/6
switchport mode trunk
switchport trunk native vlan 20
switchport trunk allowed vlan 20,1000

Table of Contents