Table 5. Operating and non-operating temperature considerations (continued)
Description Temperature range
Ambient temperature for rear air-fllow (RAF)
and normal air-flow (NAF) with GPU
45°C
Non-operating temperature range -40 to 85°C
Environmental Considerations
The PowerEdge XR4000w system is targeted for edge deployments and it meets all the additional standards for thermal, shock,
vibration parameters.
Table 6. Environmental considerations
Industry Configuration Description
Telco GR-1089-CORE Electromagnetic Compatibility and Electrical Safety
Generic Criteria for Network Telecommunications
Equipment
GR-63-CORE NEBS Requirements: Physical Protection
SR-3580 (NEBS Level 3) NEBS Criteria Levels
GR-3108-CORE (Class 1) Network Equipment in the Outside Plant (OSP). An
exception is made for cold boot at 0C instead of -5C.
Military MILSTD 810H Environmental engineering considerations and
laboratory test
MILSTD 461G/// Requirements for the control of electromagnetic
interference characteristic of subsystems and
equipment
MILSTD 901E High impact shock test Shipboard
MILSTD 1474E Department of Defense Design Criteria Standard
Noise Limits
Marine IEC-60945 Maritime navigation and radiocommunication
equipment and systems General requirements
DNV-GL Environmental Test Specification for Instrumentation
and Automation Equipment
Power Industry IEEE 1613 Environmental and testing requirements for
communications networking devices in electric power
substations
IEC 61850-3 Communication networks and systems for power
utility automation
Safety NA LDV, IEC/EN, CFR, CSA
EMC NA EN, CISPR, ES, DTAG, CFR, ICES, VCCI
EMV NA RoHS, WEEE, EN, ECE