EasyManua.ls Logo

Dell PowerVault - Page 391

Dell PowerVault
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
create virtualDisk raidLevel=5 userLabel="2"
physicalDisks=[0,1 0,6 1,7 1,3 2,3 2,6] owner=1
segmentSize=16 capacity=2GB;
show "Setting additional attributes for virtual
disk 7";
//Configuration settings that cannot be set during
virtual disk creation
set virtualDisk["7"] mediaScanEnabled=false;
set virtualDisk["7"] consistencyCheckEnabled=false;
set virtualDisk["7"] modificationPriority=high;
The command in this example, like the create virtualDisk command in the previous example,
creates a new virtual disk. The significant difference between these two examples is that this example
shows how you can define specific physical disks to include in the virtual disk. To find out what physical
disks are available in a storage array, run the show storageArray profile command.
The following syntax is the general form of the create virtualDisk command shown in the previous
example:
create virtualDisk raidLevel=(0 | 1 | 5 | 6)
userLabel="virtualDiskName" physicalDisks=
(enclosureID0,slotID0... enclosureIDn,slotIDn)
[capacity=virtualDiskCapacity | owner=(0 | 1) |
segmentSize=segmentSizeValue]
[enclosureLossProtect=(TRUE | FALSE)]
391

Table of Contents

Other manuals for Dell PowerVault