Chapter 6 Control Mode of Operation ASDA-M
6-22 Revision December, 2014
P1-25
VSF1
Low-frequency Vibration Suppression
(1)
Address: 0132H
0133H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.9
Operational
Interface
:
Panel / Software Communication
Default:
1000
Control
Mode
:
PT / PR
Unit:
0.1 Hz
Range:
10 ~ 1000
Data Size:
16bit
Format:
DEC
Example:
150= 15 Hz
Settings:
The setting value of the first low-frequency vibration suppression.
If P1-26 is set to 0, then it will disable the first low-frequency filter.
P1-26
VSG1
Low-frequency Vibration Suppression
Gain (1)
Address: 0134H
0135H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.9
Operational
Interface
:
Panel / Software Communication
Default:
0
Control
Mode
:
PT / PR
Unit:
-
Range:
0 ~ 9 (0: Disable the first low-frequency
filter)
Data Size:
16bit
Format:
DEC
Settings:
The first low-frequency vibration suppression gain. The bigger the
value it is, the better the position response will be. However, if the
value is set too big, the motor will not be able to operate smoothly.
It is suggested to set the value to 1.