ASDA-M Chapter 6 Control Mode of Operation
Revision December, 2014 6-23
P1-27
VSF2
Low-frequency Vibration Suppression
(2)
Address: 0136H
0137H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.9
Operational
Interface
:
Panel / Software Communication
Default:
1000
Control
Mode
:
PT / PR
Unit:
0.1 Hz
Range:
10 ~ 1000
Data Size:
16bit
Format:
DEC
Example:
150 = 15 Hz
Settings:
The setting value of the second low-frequency vibration
suppression. If P1-28 is set to 0, then it will disable the second
low-frequency filter.
P1-28
VSG2
Low-frequency Vibration Suppression
Gain (2)
Address: 0138H
0139H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.9
Operational
Interface
:
Panel / Software Communication
Default:
0
Control
Mode
:
PT / PR
Unit:
-
Range:
0 ~ 9 (0: Disable the second
low-frequency filter)
Data Size:
16bit
Format:
DEC
Settings:
The second low-frequency vibration suppression gain. The bigger
the value it is, the better the position response will be. However, if
the value is set too big, the motor will not be able to operate
smoothly. It is suggested to set the value to 1.