ASDA-M Chapter 8 Parameters
Revision December, 2014 8-21
Settings
The setting value which is set by P0-17 should be monitored via
P0-09. (Please refer to Chapter 7.2.1, Description of Monitor
Variable for the setting value.)
For example, if P0-17 is set to 3, when accessing P0-09, it
obtains the total feedback pulse number of motor encoder. For
MODBUS communication, two 16bit data, 0012H and 0013H will
be read as a 32bit data; (0013H : 0012H) = (Hi-wordLow-word).
Set P0-02 to 23, the panel displays VAR-1 first, and then shows
the content of P0-09.
P0-10
CM2 Status Monitor Register 2
Address: 0014H
0015H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 4.3.5
Operational
Interface
Panel / Software Communicaiton
Default
-
Control
Mode
ALL
Unit
-
Range
-
Date Size
32bit
Format
DEC
Settings
The setting value which is set by P0-18 should be monitored via
P0-10. (Please refer to Chapter 7.2.1, Description of Monitor
Variable for the setting value.) Set P0-02 to 24, the panel displays
VAR-2 first, and then shows the content of P0-10.
P0-11
CM3 Status Monitor Register 3
Address: 0016H
0017H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 4.3.5
Operational
Interface
Panel / Software Communicaiton
Default
-
Control
Mode
ALL

Table of Contents

Other manuals for Delta ASDA-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-M Series and is the answer not in the manual?

Delta ASDA-M Series Specifications

General IconGeneral
BrandDelta
ModelASDA-M Series
CategoryServo Drives
LanguageEnglish

Related product manuals